How to solve this issue Variable 'X' is not fully defined on some execution paths.

Illustration
Castillo - 2021-09-13T15:56:41+00:00
Question: How to solve this issue Variable 'X' is not fully defined on some execution paths.

Dear All,   I have a code into a MATLABFUNCTION block of Simulink that jump out this error message "   Variable 'CONDICIONTRAMO' is not fully defined on some execution paths. Function 'Battery_Control/Function_Cruz_v2' (#25.1881.1895), line 57, column 12: "CONDICIONTRAMO" Launch diagnostic report."   Anyone of you can help me out to find the way to solve this ? Please.   function [SOC_CC, Bat_charge] = BUsage(top, SOC, SOC_Seg, SOCint, W_demand, Power_PV) if SOC>=SOC_Seg SOC_CC=0; Bat_charge=0; return else if SOC>=SOCint SOC_CC=1; Bat_charge=0; end if SOC<=SOCint if (top>=8)||(top<=9) && Power_PV>W_demand CONDICIONTRAMO = 1; disp('Llano 1 de 8 a 9') elseif (top>=8)||(top<=9) && Power_PV=10)||(top<=13) && Power_PV>W_demand CONDICIONTRAMO = 3; disp('Punta 1 de 10 a 13') elseif (top>=10)||(top<=13) && Power_PV=14)||(top<=17) && Power_PV>W_demand CONDICIONTRAMO = 5; disp('Llano 2 de 14 a 17') elseif (top>=14)||(top<=17) && Power_PV=18)||(top<=21)&& Power_PV>W_demand CONDICIONTRAMO = 7; disp('Punta 2 de 18 a 21') elseif (top>=18)||(top<=21)&& Power_PV=22)||(top<=23)&& Power_PV>W_demand CONDICIONTRAMO = 9; disp('Llano 3 de 22 a 23:59') elseif (top>=22)||(top<=23)&& Power_PV=24)||(top<=8) && Power_PV  

Expert Answer

Profile picture of Neeta Dsouza Neeta Dsouza answered . 2025-11-20

Insert a definition of CONDICIONTRAMO = -1 (or NaN, or 12) either on top of the code, before the IF branchs, or in a finaly else branch:
 
 
...
        elseif (top>=24)||(top<=8) && Power_PV
But then Bat_charge is not defined in all branchs. Add a default value for this variable also.
 
By the way, the Switch/Case-Block is hard to read. Maybe this is tougher:
 
%               1 2 3 4 5 6 7 8 9 10 11 12
SOC_CC_V     = [1 0 1 0 1 0 1 0 1 0  1  NaN];
Bat_charge_V = [0 0 0 0 0 0 0 0 0 0  1  NaN];

SOC_CC     = SOC_CC_V(CONDICIONTRAMO);
Bat_charge = Bat_charge_V(CONDICIONTRAMO);


Not satisfied with the answer ?? ASK NOW