The most basic control law you could consider is a purely proportional control law, where if we
assume the state you want to control is called x, the control inputs are
u = -K*x
this type of control law has the advantage of being very simple, but in most cases its
performance will be inadequate because the system will not have the right amount of damping; it
would be expected to oscillate. A more complex control law is a PD law:
u = -Kp*x -Kd*dx/dt
The challenge here is that if your state vector is contaminated by noise (which is almost always
the case) and you cannot directly sense the rate of change of x (which is also very common) then
estimating dx/dt can be difficult. Taking a numerical difference, which seems tempting, has the
effect of amplifying the noise and causing the tracking behavior to be poor. So one common thing
to do in this case is to filter the state vector and use the filtered version to estimate the
rate of change of x. The downside to this is that the filter will add some lag to the system,
which can be destabilizing.
Depending on the order of the system, you can also try a PI controller or a PID controller. The
systems I am familiar with do not use PI controllers, but I know they are used. PID controllers
are typically only used when there is a steady state disturbance that you need to compensate for
but cannot increase the Kp gain enough to compensate for it adequately.